3-3 Phase On Line UPS (10 -160 KVA )

General:
  • Type: Online double-conversion UPS, 10 kVA (10 kilowatts) capacity.
  • Phase: 3-phase input and 3-phase output (3/3).
  • Topology: Online double-conversion, providing the highest level of power conditioning and protection. 
Input:
  • Voltage: Typically configurable for 380/400/415Vac (3-phase + N + PE).
  • Voltage Range: Wide input voltage range, often 270-480Vac.
  • Frequency: 50/60Hz with auto-sensing. 
Output:
  • Voltage: 380/400/415Vac (3-phase + N + PE).
  • Voltage Regulation: Typically ±1% for linear load.
  • Frequency: 50/60Hz ±0.1Hz.
  • Waveform: Pure sine wave.
  • Distortion (THDu): Typically <3% for linear load.
  • Crest Factor: 3:1 (minimum) at full load.
  • Overload Capacity:
    • 110% for 60 minutes
    • 125% for 10 minutes
    • 150% for 1 minute
  • Transfer Time:
    • Mains to Battery: 0 ms
    • Battery to Mains: 0 ms
    • Inverter to Bypass / Bypass to Inverter: Typically 2-4ms. 
Guarantee safe & secure checkout
Guarantee & safe checkout
SKU : Woo-beanie-logo Category : Tag : Brand:

Description

General:
  • Type: Online double-conversion UPS, 10 kVA (10 kilowatts) capacity.
  • Phase: 3-phase input and 3-phase output (3/3).
  • Topology: Online double-conversion, providing the highest level of power conditioning and protection. 
Input:
  • Voltage: Typically configurable for 380/400/415Vac (3-phase + N + PE).
  • Voltage Range: Wide input voltage range, often 270-480Vac.
  • Frequency: 50/60Hz with auto-sensing. 
Output:
  • Voltage: 380/400/415Vac (3-phase + N + PE).
  • Voltage Regulation: Typically ±1% for linear load.
  • Frequency: 50/60Hz ±0.1Hz.
  • Waveform: Pure sine wave.
  • Distortion (THDu): Typically <3% for linear load.
  • Crest Factor: 3:1 (minimum) at full load.
  • Overload Capacity:
    • 110% for 60 minutes
    • 125% for 10 minutes
    • 150% for 1 minute
  • Transfer Time:
    • Mains to Battery: 0 ms
    • Battery to Mains: 0 ms
    • Inverter to Bypass / Bypass to Inverter: Typically 2-4ms. 

Reviews

There are no reviews yet.

Be the first to review “3-3 Phase On Line UPS (10 -160 KVA )”

Your email address will not be published. Required fields are marked *

Quick Comparison

3-3 Phase On Line UPS (10 -160 KVA ) removeEPOWER-L Series 10-160kVA removeHP900C Series removeBH Series HF online UPS (1-10KVA 1/1 Phase) removeEPOWER SERIES 10-800kva removeOnline low Frequency Transformer based Ups 1-30kva (1/1 Phase 3/1 Phase) remove
Name3-3 Phase On Line UPS (10 -160 KVA ) removeEPOWER-L Series 10-160kVA removeHP900C Series removeBH Series HF online UPS (1-10KVA 1/1 Phase) removeEPOWER SERIES 10-800kva removeOnline low Frequency Transformer based Ups 1-30kva (1/1 Phase 3/1 Phase) remove
Image3-3 Phase On Line UPS (10 -160 KVA )EPOWER-L Series 10-160kVAHP900C SeriesBH Series HF online UPS (1-10KVA 1/1 Phase)EPOWER SERIES 10-800kvaOnline low Frequency Transformer based Ups 1-30kva (1/1 Phase 3/1 Phase)
SKUWoo-beanie-logo
Rating
Price
Stock
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Description
General:
  • Type: Online double-conversion UPS, 10 kVA (10 kilowatts) capacity.
  • Phase: 3-phase input and 3-phase output (3/3).
  • Topology: Online double-conversion, providing the highest level of power conditioning and protection. 
Input:
  • Voltage: Typically configurable for 380/400/415Vac (3-phase + N + PE).
  • Voltage Range: Wide input voltage range, often 270-480Vac.
  • Frequency: 50/60Hz with auto-sensing. 
Output:
  • Voltage: 380/400/415Vac (3-phase + N + PE).
  • Voltage Regulation: Typically ±1% for linear load.
  • Frequency: 50/60Hz ±0.1Hz.
  • Waveform: Pure sine wave.
  • Distortion (THDu): Typically <3% for linear load.
  • Crest Factor: 3:1 (minimum) at full load.
  • Overload Capacity:
    • 110% for 60 minutes
    • 125% for 10 minutes
    • 150% for 1 minute
  • Transfer Time:
    • Mains to Battery: 0 ms
    • Battery to Mains: 0 ms
    • Inverter to Bypass / Bypass to Inverter: Typically 2-4ms. 
Key Features and Specifications:
  • Capacity: 10-160kVA.
  • Phase Configuration: 3:3 (3-phase input and 3-phase output).
  • Power Factor: 0.8.
  • Technology: Double conversion on-line.
  • Input Voltage Range: 165-275Vac.
  • Input Frequency Range: Ensures stable operation with various fuel generators.
  • Output Voltage: 380/400/415Vac.
  • Frequency: 50/60Hz (±5%).
  • Efficiency: High efficiency.
  • Operating Temperature: 0-40°C.
  • Storage Temperature: -25 to 55°C.
  • Humidity: 0-95% (non-condensing).
  • Noise Level: Less than 58dB at 1 meter.
  • Standards: Complies with IEC/EN 62040-3 and IEC/EN 62040-2.
  • Communication: Includes communication interfaces.
  • Battery Cold Start: Can be started directly from the battery in the absence of utility power.
  • Built-in Isolation Transformer: Provides strong anti-interference ability and comprehensive protection.
  • Self-Diagnosis: Includes a self-diagnosis function before startup.
  • Comprehensive Protections: Offers overload, short-circuit, and other protections. 
Key Specifications:
  • Technology: Double conversion online UPS with fully digitized microprocessor control. 
  • Power Ranges: 1-3kVA and 6-10kVA. 
  • Input: Wide voltage range, single-phase (1:1 phase) or three-phase in, single-phase out. 
  • Output: Pure sine wave output. 
  • Features:
    • Cold start capability. 
    • Automatic battery charging in UPS off mode. 
    • Short circuit and overload protection. 
    • Fan speed auto-control based on load. 
    • Optional SNMP card slot and extension battery pack. 
  • Communication: Smart RS232 communication with monitoring software. 
  • Parallel Capacity: Can be paralleled up to 3 units. 
  • Applications: Suitable for servers, networking equipment, and other critical loads. 
Technology points ◆ Fully DSP control online UPS which provide outstanding stability and reliability; ◆ Output PF=1.0, overall efficiency above 95%; ◆ Intelligent battery management, UPS charging current can be adjustable from 1-12A; ◆ Powerful overload ability with output short circuit protection technology which can high make sure the UPS reliability and system safety under critical status; ◆ Large Color Dot-matrix LCD+LED Screen with multi function and user- friendly.
Typical Specifications (may vary by model):
  • Capacity: 10kVA to 800kVA. 
  • Input Voltage: 380/400/415 VAC (±25%), ±10%, ±20% (depending on model and setting). 
  • Input Frequency: 45-65 Hz or 50/60 Hz ±5 Hz. 
  • Output Voltage: 380/400/415 VAC (±1%). 
  • Output Frequency: 50/60 Hz ±0.5%. 
  • Efficiency: Up to 96% or higher (depending on model and mode). 
  • Transfer Time: Typically 0ms from line mode to battery mode, 1ms for inverter fault, and 0ms for bypass transfer. 
Key Specifications and Features:
  • Capacity:
    Typically available in 1kVA, 2kVA, 3kVA, 6kVA, 10kVA, 15kVA, 20kVA, and 30kVA models. 
  • Phase Configuration:
    Can be either single-phase (1:1) or three-phase (3:1). 
  • Input/Output Voltage:
    Single-phase models often operate with input and output voltages around 220/230/240VAC, while three-phase models may offer configurations like 380/400/415VAC. 
  • Frequency:
    Operates at standard frequencies like 50Hz or 60Hz, with some models offering frequency conversion capabilities. 
  • Online Double Conversion:
    These UPS systems utilize online double-conversion technology, ensuring continuous power delivery by converting AC to DC and then back to AC, providing clean and stable power. 
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Home
Shopping
Wishlist
Account